UPS LTD - Practical Considerations For Sizing Your UPS System

Choosing a UPS with the right capacity for your commercial or industrial application may appear as a simple task. In reality however, making the correct choice depends on knowledge and understanding of your site’s load and its characteristics. This usually involves a site survey to determine not only the nature of the critical load but also how it varies over time. Authored by Matt Henley, Technical Sales Manager for Uninterruptible Power Supplies Limited, this article looks at these issues and explains how to allow for them when choosing a UPS for installation on your site.

Although typically associated with data centres, Uninterruptible Power Supply (UPS) systems are finding their way into an ever-widening, diverse range of environments. This is due to the increasing number of telecoms, medical, industrial processing, retail and other applications that now rely critically on electrical equipment and power availability. Such applications impose widely varying loads on their UPSs; these must be understood and quantified to allow selection of an adequate, cost-effective UPS solution.

Clearly the load at any given site will be unique, depending on the mix of equipment in its make-up. However, the load will also be time-variant in several ways. There will be daily and weekly variations as office occupancy and equipment use drops overnight or during weekends and holidays, as well as seasonal variations in the weather, and demand on air-conditioning or heating changes. Longer term changes arising from operational expansion and the addition of new equipment are also likely. Investigation of the critical load’s on site components, including measurement of the load’s performance over a meaningful time, is a necessary part of the UPS sizing exercise.

Within the UK, the UPS is usually fed from the National Grid electrical mains, and feeds the site’s critical load. During a mains failure, the UPS batteries maintain supply. To start sizing the UPS, the load should be scoped in terms of its required supply voltage, frequency, number of phases, load current, power factor and power consumption. Equipment supply voltage is usually stated on an attached label or plate, or within the manufacturer’s literature. The UK supply voltage prior to EU harmonization was 240 V; even after harmonization at 230 V the UK grid could still be (and usually is) run at 240 V nominal while remaining within EU harmonized tolerance. Meanwhile, equipment, especially if supplied into Europe, could be rated at 220, 230 or 240 V. Therefore it is important to check that the UPS output voltage is within the tolerance of all on site equipment.

Equipment should also be compatible with the UK’s nominal frequency of 50 Hz, and may be single- or three-phase. Whereas a three-phase UPS can supply both single- and three-phase loads, a single-phase UPS can only supply single-phase loads.

UPS manufacturers express their products’ power capability in VA or kVA. Meanwhile, equipment power consumption may be expressed in Watts. If so, its contribution to the load in VA can be found by multiplying its load current by its supply voltage. Alternatively its power consumption in Watts can be divided by its stated Power Factor to reveal its VA load. Manufacturers frequently overstate their equipment consumption by 20% or so to ensure the installer provides an adequate supply; however this over-rating cannot be relied on, and if in doubt the load should be measured.

This measurement activity can form part of the overall site survey. This should include installing portable measuring and monitoring equipment to record information about the load over a period of time. The period depends on the site situation; for example it would be misleading to monitor an office network over a weekend when very few staff have their PCs on.

The nature as well as the size of the load should be considered. Although UPSs are generally resilient, certain load types do present challenges which must be allowed for. These include blade servers, fluorescent gas discharge lighting, motors and compressors, air conditioning equipment and laser printers. These can all draw high currents during normal operation, and even higher inrush currents during start-up. This may overload the UPS causing a transfer to bypass.

Blade servers also impact UPSs in another way. Unlike equipment with a lagging power factor, blade servers present a leading power factor. As these servers are powerful and increasingly popular within computer installations, the critical load’s overall power factor may become leading. This presents a major problem with legacy transformer based UPS systems. For example a 300 kVA UPS requires derating by 24% for a 0.9 leading power factor. By contrast, a modern transformerless 300 kVA derates at 0.9 leading power factor.

Harmonic currents, if present, cause increased reactive power and therefore degrade the power factor. This can drop to 0.7 or less if no corrective measures are taken. However all computer power supplies, to comply with EU Standard EN61000-3-2, must include at least passive power factor correction. Loads that generate harmonic currents also tend to generate high peak currents. For computer systems, these can be as much as 2.5 times the steady-state value. For linear loads, however, the peak factor is closer to 1.42.

If a three-phase UPS is supplying a load with single-phase components, these components should be distributed as evenly as possible between the phases to allow the capacity of the UPS to be optimally utilized. A balanced load is also presented to the mains or, if installed, the generator if the UPS is bypassed. Although modern UPS systems can cope with phase imbalance, the load on any single phase must never exceed 33% of the total UPS loading. If single-phase loads driven by different phases of a three phase UPS are physically close to one another, Regulation 514-10-01 of BS7671 must be enforced to ensure personnel safety.

When all the load information has been collected, measured and collated, the required UPS capacity will become apparent. It is normal practice to add contingency capacity of typically 20% to this value. Additionally it is essential to carefully consider the site’s future expansion plans and allow for these in the UPS configuration accordingly. If modular UPS technology is used, the only initial requirement is to allow sufficient racking space, as more rackmounting UPS modules can easily be added when site expansion demands extra capacity.

The load’s criticality will also influence the final decisions on the UPS’s size and configuration. Most applications today, from online commercial operations to medical facilities, will demand redundancy in their UPS, meaning it must be resilient to the failure of at least one of its component modules. Extended battery autonomy and standby generators are also popular options. Any reputable UPS supplier will be able to help with site surveys, discuss the criticality of the load, and advise on UPS configuration and sizing accordingly.


Artemide Architectural lighting Lighting systems Down lights Internal lighting News 121011

Balcony Systems Glass balconies Juliet balconies Glass balustrades Patio doors News 131011

Bilco Roof vents Automatic vents Smoke ventilation Roof hatches News 111011

Brett Martin Plastic sheets Drainage pipe Plastic pipe Rainwater systems News 131011

Cembrit Roof tiles Fibre cement slates Fibre cement cladding News 111011

Clipso Wall panels Stretch ceilings Fabric ceilings Acoustic ceilings News 141011

Collingwood Lighting systems Commercial lighting LED lights Strip lighting News 141011

Dimplex Electric heating Heat pumps Space heaters Air curtains News 121011

Dow Insulation products Floor insulation Roof insulation Wall insulation News 121011

Dulux Trade Dulux paint Dulux trade Trade paint Gloss paint News 121011

Ergolet Lifting hoists Disabled toilets Lifting systems Hoist systems News 121011

Flakt Woods Air handling Ventilation systems Roof ventilation Roof fans News 131011

Forbo Flooring Systems Flooring systems Carpet tiles Floor coverings Linoleum flooring News 141011

Forticrete Concrete products Building products Roof tiles Walling stone News 141011

GreenBrook Cabinet lights Lighting systems Electrical products LED lighting News 131011

Hanson Formpave Block paving Block paving bricks Water harvesting systems News 111011

Jablite Insulation products Roof insulation Wall insulation Floor insulation News 141011

Jeld-Wen Internal doors External doors Sliding doors French doors News 121011

John Brash Decking boards Antislip decking Timber decking Roof battens News 121011

Knauf Marmorit External wall insulation Insulation products Knauf wall insulation News 121011

Komfort Office partitions Glass partitions Movable walls Glass doors News 131011

Lakesmere Building services Rainscreen cladding Flat roofs Curtain walling News 131011

Marley Alutec Aluminium gutters Drainage systems Drainage pipe Rainwater system News 131011

Marley Alutec Rainwater systems Aluminium gutters Gutter systems Aluminium downpipes News 121011

Marley Eternit Fibre cement cladding Weatherboard cladding Cladding fixing systems News 131011

Marley Eternit Slate tiles Roof tilesInterlocking tiles Clay tiles News 141011

Marshall-Tufflex Cable management Electrical switches Cable trays Waterproof switches News 141011

Marshall-Tufflex Cable management Energy management Data services Cable trays News 111011

Megaman Energy Saving Tips Lighting Tips Luxmeter iPhone App News 101011

MG Renewables Solar panels PV systems Photovoltaic panels Solar heating News 121011

Northcot Brick Clay bricks House bricks Facing bricks Handmade bricks News 131011

Panasonic Air conditioning Air control Air system Air ventilation News 141011

Passivent Natural ventilation Passive ventilation Natural daylight Domestic ventilation News 141011

Siemens Building management systems BMS systems Building automation systems News 111011

Socomec UPS System Emergency Power Static UPS Electrical Switchgear News 101011

Spilka Window hinges Aluminium window hinges Patio door hinges News 131011

Stewart Milne Timber frame construction Timber frame buildings Timber frame News 131011

Sustainable Options Street furniture Plastic benches Plastic tables Plastic fencing News 121011

Thorn Lighting products Internal lighting Commercial lighting LED lighting News 141011

Total Home Environment Heat pumps Heat recovery ventilation Central vacuum systems News 141011

Trox Energy efficiency Air conditioning Chilled beams Ventilation systems News 101011

Wade Drainage products Floor drains Roof drainage Linear drainage News 121011

Washroom Washroom Bathroom suites Shower cubicles Vanity units Bathroom sinks News 141011

Windhager Biomass boilers Solar thermal systems Central heating cooker News 141011

News Categories:
Uninterruptible power supply UPS systems Standby power systems

Arundel Jones Associates Ltd
Hill Farm Business Park, Linton Hill, Maidstone, Kent ME17 4AL
Tel : 01622 745333

news@buildingdesign.co.uk


See also:

| BuildingDesign Directory | BuildingDesign Tenders |

|BuildingDesign News Archives | 2006 | 2007 | 2008 | 2009

| BuildingDesign Recruitment | AJA Part Time Jobs Board |

© 2010 copyright all rights reserved Registered in England and Wales No. 07334149