BAXI-SENERTEC UK - CHP Units Rise To University Challenge

Baxi-SenerTec UK is helping the University of Central Lancashire (UCLan) to meet its building energy management objectives with the installation of a pair of its Dachs Mini-CHP (combined heat and power) units.

UCLan, one of the largest universities in the UK with a student and staff community of more than 35,000, is in the middle of a programme to install on-site power generation technology that can reduce its need for grid connected electricity and help it “deliver year-on-year reductions in CO2 emissions”.

As part of this plan, the university installed two of Baxi-SenerTec’s Dachs Mini-CHP units, which generate electricity and provide heat for its Victoria Building. The units have been running for nearly a year and have proved so successful that the university is now looking for other potential sites where it can use CHP.

The four-storey building is home to the Northern School of Design and includes art studios, offices, a cafe and exhibition spaces in its 7,453 sq m gross floor area. It was built in 1983 and two gas atmospheric boilers were installed at the time.

However, by early 2008, they needed to be replaced, as Andrew Poole, a director of building services consultant BES, explains: “We were engaged originally to undertake a boiler replacement design because the boilers had reached the end of their useful life.

Strategy
“We initially produced a specification for replacement boilers, but subsequently we were asked to rework the design to incorporate CHP because the FM department felt that would be better for its energy strategy.”

Ruth Taylor, energy and carbon management officer, at UCLan had read an article about a Dachs CHP installation. She says: “That was the spark. We were interested in CHP because of the variable demands on the site. In the summer, we don’t have the same number of students and we needed something smaller to fit the existing space. The Baxi-SenerTec units fitted the bill perfectly and were a safe option.”

The key to a successful CHP installation is to ensure that the engine runs for as long as possible to generate low cost electricity. It is therefore essential to know that almost all of the heat produced by the engine can be used in the building.

If the building’s heat, or hot water demand falls below the minimum heat output of the CHP, the engine will switch off until the heat demand is re-established, meaning loss of electricity generation. The number of Dachs modules installed should, therefore, match the minimum, or base, heat demand of the building.

However, the Victoria Building’s demand is difficult to predict because of its variable occupancy levels. BES, therefore, came up with a design incorporating two Dachs units as lead boilers plus six condensing modulating boilers. However, the design includes space and connections ready for a third Dachs unit to be dropped in should the heat load demand it in future.

Mr Poole says: “I had never used Dachs units on a project before, but Baxi-Senertec provided excellent specification and usage information. The company was proactive in getting the relevant design information across to us so that we could develop the most appropriate scheme for this application.”

The Dachs units were installed by Preston-based mechanical building services engineering company James Mercer Group. They are designed for continuous running with a design life of around 80,000 running hours. The reliable internal combustion engine drives a three-phase electrical generator, and the heat generated by the engine is captured and transferred to the building’s heating system.

The Grid will make up any power shortfall from the system’s electricity generation, and any excess power generated by the CHP will be automatically exported in the other direction.

Mrs Taylor says: “We have been impressed with the Baxi units. They are running constantly and we are waiting to see how they handle the summer. The trial so far has been such a success we are now looking at other projects where we can install these units including, possibly, a building with a refectory.”


3M Insulation bonding Insulation adhesive Roof adhesive Roofing materials News 020911

Action Storage Storage lockers Storage systems Plastic lockers Steel lockers News 300811

Ancon Building products Wall ties Support systems Tension systems News 010911

Belimo Valve actuators Control valves Air dampers Smoke dampers News 310811

Bilco UK Roof hatches Smoke vents Access equipment Smoke ventilation News 010911

Carlo Gavazzi Energy management Energy meters Building automation Lighting sensors News 010911

Catnic Steel lintels Timber frame lintels Cavity wall lintels News 310811

Danfoss Speed drives Danfoss drives Danfoss inverters Danfoss valves News 310811

Eaton Power management Photovoltaic systems Electrical distribution Electrical products News 020911

Flowcrete Resin flooring Commercial flooring Industrial flooring Floor screed News 010911

Formica Formica laminate Formica sheets Laminate sheets Laminate products News 020911

Formica Formica surfaces Formica worktops Formica tabletops Formica tables News 300811

Gent by Honeywell Fire alarms Fire detection Emergency lighting Fire sensors News 020911

Ibstock Ibstock bricks Brick pavers Brick slips Glazed bricks News 300811

Kalzip Standing seam roofing Low U-valve roofing Metal roofing and cladding Solar solutions Green roof systems News 300811

Kawneer Aluminium systems Curtain walling Rainscreen cladding Solar shading News 010911

Knauf Insulation Insulation products Wall insulation Roof insulation Floor insulation News 300811

Leaderflush Shapland Timber doorsets Door sets Door hardware Timber doors News 310811

Levolux Solar shading Ventilation louvres External louvres Solar shade News 300811

PMA Cable protection Cable management Structured cabling Flexible fittings News 310811

Sandtex Trade Exterior paint Sandtex paint Masonry paint Sandtex trade News 010911

South Facing Solar PV Solar panels Renewable energy Solar photovoltaics News 020911

Spirax Sarco Steam meters Steam systems Steam heating Heat recovery News 310811

Tarkett Commercial flooring Vinyl flooring Safety flooring Vinyl tiles News 310811

Vent-Axia Commercial ventilation Domestic ventilation Heat recovery Air curtains News 010911

Weatherite Building services Water storage systems Air conditioning systems News 300811

News Categories:
CHP units High efficiency boilers Baxi combi boiler

Arundel Jones Associates Ltd
Hill Farm Business Park, Linton Hill, Maidstone, Kent ME17 4AL
Tel : 01622 745333

news@buildingdesign.co.uk


See also:

| BuildingDesign Directory | BuildingDesign Tenders |

|BuildingDesign News Archives | 2006 | 2007 | 2008 | 2009

| BuildingDesign Recruitment | AJA Part Time Jobs Board |

© 2010 copyright all rights reserved Registered in England and Wales No. 07334149