TROX UK - Low Ceilings No Problem For New Trox High Capacity Active Chilled Beam

A new launch from TROX UK makes it possible to improve air handling and energy efficiency significantly, even where low false ceiling voids would previously have ruled out active chilled beams.

The new DID632 active chilled beam from TROX has a height of only 210mm, making it ideal for use in new or existing buildings with clear room heights of 2.6m to 4m. It is designed for rooms with a high cooling load, and combines optimum comfort conditions with outstanding energy efficiency. The cooling capacity is even higher than its predecessor (the DID 600B), at a lower rate of primary air flow (maximum of 2,500 watts at 70 l/s). This is made possible by optimised nozzle configuration and unit geometry which delivers an increased capacity from a more compact chilled beam unit.

Air velocity in the occupied zone is reduced due to adjustable blades which control the direction of the air discharge. The DID632 also incorporates features for quiet and extremely reliable operation.

Four different induced air grille designs enable the specifier opportunities to enhance the aesthetic appeal of the ceiling space with standard product lines.

There is also a choice of two types of heat exchanger. One is a two pipe system for cooling, which enables heating to be provided using a changeover mode. The other is a four pipe system which enables any room to be cooled or heated independently of other rooms. Eight nominal lengths, each having four different nozzle options, make it possible to select the optimum unit to meet the air flow rate and thermal capacity requirements of the room, with the lowest air differential pressures and minimum sound power levels.

Operation
Active chilled beams supply conditioned fresh air (primary air) to the space from a central plant room to maintain indoor air quality. At the same time, additional cooling/heating is provided using heat exchangers.

The DID632 discharges primary air into the beam mixing chamber via nozzles. As a result, secondary air is induced (via an inlet grille) and passes through a heat exchanger into the mixing chamber. Here it is mixed with the primary air, and the total supply air is discharged horizontally into the space through integral slot diffusers.

E-mail TROX UK

TROX UK Product Information


Abacus Lighting New Factory In Shanghai China News 020211

Actionair Ruskin Air Management Website Launch News 310111

Ardex Ultra Rapid Setting Levelling Compound News 030211

Armstrong Ceilings Latest A Book Interior Solutions News 310111

Blucher Launch New Products Ecobuild News 020211

Eaton Williams Agreement With Alessa Industries News 010211

Eco Fence And Doors Doors Available To Exact Measurements News 040211

Elliott Eco Cabin Portable Buildings News 310111.htm

Emerson Chloride Trinergy UPS Endorsed Ireland News 010211

Gradient CPD Presentation Single Layer Tapered Roofing News 040211

Hanson Formpave CPD Seminars Storm Water Control System News 010211

Harlequin Dance Floors Prix De Lausanne News 040211

Hoard It Perimeter Hoarding Premier Inn Olympic Athletes News 310111

Ideal Standard New Brand Strategy 2011 New Products News 040211

Isover Thermal Bypass Solution Insulation News 040211

Kawneer Sustainability Criteria Architectural Aluminium Systems News 310111

Osram Powertronic PTo 3DIM Electronic Control Gear News 310111

Passivent Achieve Zero Carbon Tesco Tweedmouth News 020211

Polyflor Commercial Luxury Vinyl Floor Tiles News 030211

Powrmatic NVx Range Gas Suspended Unit Heaters News 020211

Prysmian Electrical Cables The Shard News 040211

Riegens Lighting At Dundee University News 040211

S and P Coil Products Low Carbon And Energy Saving Ecobuild 2011 News 030211

Sandtoft Restoration Project Castle Howard Estate News 030211

SAS International Products Installed At The Souk Abu Dhabi News 030211

Siemens Interactive Building Management Systems News 030211

Sunbell Designers And Manufacturers Interstial Blinds News 040211

Tarkett Flooring Balanced Choice Tags News 040211

Telling BREEAM Telling Rainscreen Cladding System News 310111

Timberplay Play Equipment Crow Wood Playscape Lyme Park News 040211

Trox Boosts Team For London Office News 020211

News Categories:
Active chilled beams Air handling Fan coil units

Arundel Jones Associates Ltd
Hill Farm Business Park, Linton Hill, Maidstone, Kent ME17 4AL
Tel : 01622 745333

news@buildingdesign.co.uk


See also:

| BuildingDesign Directory | BuildingDesign Tenders |

|BuildingDesign News Archives | 2006 | 2007 | 2008 | 2009

| BuildingDesign Recruitment | AJA Part Time Jobs Board |

2010 copyright all rights reserved Registered in England and Wales No. 07334149